| Low,medium
and high-temperature cooling towers |
|
Used for the cooling of water temperature in the
civil and industrial application such as the water circulating systems
in hotels, hospitals and power plants etc.
TYPE:
1. DBNL3-10~1000T/H low-noise counterflow type FRP cooling tower,
inlet water temperature: T1=37℃; outlet water temperature: T2=32℃;
noise: 55~65DB; temperature difference: 5℃
2. CBNL3-10~600T/H ultra-low noise counterflow type FRP cooling tower;
inlet water temperature: T1=37℃; outlet water temperature: T2=32℃;
noise: 55~58DB; temperature difference: 5℃
3. GBNL3-50~1000T/H industrial type counterflow FRP cooling tower;
inlet water temperature: T1=43℃; outlet water temperature: T2=33℃;
noise: 55~60DB; temperature difference: 10℃~20℃
Other products: FRP air duct, horizontal flow type square FRP cooling
tower

NH type |
Steel concrete or concrete structured counterflow
cooling tower may use the big-span concrete frame structure
for the tower body and the enclosure plates of the tower body
may be made of concrete or FRP materials as per request.
High-performance FRP axial blower is used. The material for
the inner parts of the tower is non-metallic material, which
can resist the corrosion and greatly extend the service life
of the cooling tower. |

HH type |
Steel concrete or concrete structured horizontal
flow cooling tower may use the big-span concrete frame structure
for the tower body and the enclosure plates of the tower body
may be made of concrete or FRP materials as per request.
The use of high-efficient and low- resistance inner parts of
the tower makes the air and steam more evenly distributed, which
has greatly improved the working efficiency of the tower. |

HG type |
Steel structured horizontal flow type cooling
tower uses steel structure truss as the tower body featuring
compact and reasonably designed structure and easy maintenance.
|

(G)NZF type |
Steel structured counterflow type cooling tower
uses steel structure truss as the tower body featuring compact
and reasonably designed structure and easy maintenance.
The overall rigidity and strength of the tower structure may
be assured. The tower body will be subject to corrosion resistance
treatment after being pre-assembled in the factory to greatly
extend the service life of the tower. |

GBNL type |
The tower is wholly steel structured with FRP
enclosure plates; the tower body is furnished with maintenance
ladder for access to the equipments at the top of the tower
to do normal maintenance. Rotary water distributor or tube type
water distribution system may be optional by the user for water
distribution. As compared with the square tower, the performance
of air flow field is much better with higher cost-effectiveness,
which is especially suitable for clean water cooling tower.
|
|
|
|