dot Water supply series
1. Purifier & Filter Series
LTZ series gravity integrated water purifier
LTS series gravity automatic/manual new-type integrated water purifier
KGL gravity water purifier
LTG steel gravity valveless filter
GZG series steel self-cleaning high-efficiency water filter
LZS moderate speed filter and LGS high speedfilter
2. Water purification series
GJX uniflow type mechanical filter
LCT pressure type underground water ferric and manganese ion removal system
Anion and cation exchanger
LCF fluoride removal equipment
SQ type automatic mechanical filter
QL type fiber ball filter
3. RO System Series
4. Automatic water softening series
dot Drainage series
1. Domestic sewage treatment equipment
2. Intermediate water treatment equipment
3. LYS type Land-use oil-water separator
4. LQF unified air flotation equipment
dot Water circulation series
1. Low,medium and high-temperature cooling towers
2. Swimming pool circulating water equipment
Domestic made equipments
Imported equipments
dot Magnetic water treatment equipment
PRODUCTS
Domestic sewage treatment equipment
[Applicable scope]
The equipment is suitable for treatment of domestic sewage in residential areas, restaurants, hotels, sanitariums, schools, mines and factories as well for treatment of industrial wastewater with similar nature of domestic sewage
[Main characteristics]
May be buried under the earth surface
Wholly automatic control with no need of operators
No return sludge
Easy operation and convenient maintenance
Low noise and no odor
Long service life


[Type]
The underground type domestic sewage treatment equipments produced by our company include two series including WSZ-A module series and WSZ-F FRP series with treatment capacities ranging from 0.5m3/h to 50m3/h and a total of more than 30 varieties.

[WSZ-A Module Type]
1. Process description
WSZ-type sewage treatment equipment is mainly designed for the treatment of domestic sewage and similar industrial organic sewage with the contact oxidization process being used as the main treatment method, which is currently the advanced and mature biological treatment technology. The equipment is normally designed based on the domestic water quality with BOD level of the inlet water and outlet water of 200mg/l and 20mg/l respectively. The equipment consists of 6 components as following: (1) Primary sedimentation tank (2) contact oxidization tank (3) secondary sedimentation tank (4) disinfection tank and disinfection device (5) Sludge tank (6) Blower room and blower, which are described separately as following:
(1) Primary sedimentation tank: The tank is designed to be vertical flow type with rising speed of the sewage in the tank to be 0.6-0.7mm/s and the settled sludge is air lifted to the sludge tank ( Note: no primary sedimentation tank for WSZ-A 0.5-5m3h equipments)
(2) Contact oxidization tank: The water from primary sedimentation tank self flows to contact oxidization tank for biological treatment. The contact oxidization tank is divided into three stages with overall retention time of over 1 hour. The time for contact oxidization reaction of strengthened equipments may reach 6 hours. The packing used here is new type trapeziform packing featuring easy biomembrane buildup and no blockage. The surface area of the packing is 160m2/m3 and air/ water ratio in the contact oxidization tank is about 12:1 (Note: Contact oxidization tank of WSZ-A 0.5-5M3 includes two stages)
(3) Secondary sedimentation tank: The sewage after biological treatment flows to the secondary sedimentation tank. Two vertical flow type sedimentation tanks are used working in parallel. The rising speed is 0.3-0.4mm/s and the sludge is air lifted to the sludge tank (Note: Sludge of WSZ-A 0.5-5M3 equipments self flows to sludge tank)
(4) Disinfection tank and disinfection device: The retention time of the disinfection tank is 30 minutes as per “TJ14-74” standard and additional 1-1.5 hours is needed for treatment of hospital sewage. Solid chloride is used as disinfectant with dosing amount adjusted according to outlet water capacity to achieve the purpose of more chemical with more outlet water and less chemical with less outlet water. Other disinfection devices may be supplied separately. (Note: If the equipment is used for treatment of industrial wastewater, the disinfection tank and the disinfection device are not necessary)
(5) Sludge tank: The sludge from primary sedimentation tank and secondary sedimentation tank is air lifted to WSZ-A sludge tank for aerobic digestion. The clean water in the sludge tank will backflow to the contact oxidization tank for treatment; After the digestion, the residue sludge may be cleared once every 1-2 years due to its extreme less quantity. The sludge may be pumped out by dung cart through the check hole and then transported away (For WSZ-A 0.5-5M3/h equipments, the sludge may be treated through anaerobic digestion)
(6) Air blower room and air blower: The blower room of WSZ-A equipment is constructed at the top of the disinfection tank with double-layer sound insulation at the inlet. Silencer and blower filter are furnished at the air inlet to ensure no noise during the operation. 2 sets of L type ROOTS air blowers are used working alternatively and the service life of each blower is approximately 30000hours.

2. Technical data
Name
type
A-0.5
A-1
A-3
A-5
A-10
A-20
A-30
Treatment capacity (m3/h)
0.5
1
3
5
10
20
30
Blower
type
L13LD
L13LD
L12LD
L12LD
L22LD
L23LD
L32LD
Power (kw)
0.75
0.75
1.5
1.5
2.2
4
7.5
Water pump
type
AS10-2CB
AS10-2CB
AS10-2CB
AS10-2CB
AS10-2CB
AS16-2CB
AS16-2CB
Power (kw)
1.0
1.0
1.0
1.0
1.0
1.6
1.6
Water inlet
BOD5mg/l
200-400
Water outlet
BOD5mg/l
20-60
Weight (t)
2.5
4.5
6
9
9
12
15

3. Relations between the treatment capacity of WSZ-A type and the BOD5 level of inlet and outlet water
Water inlet BOD5mg/L
200
300
400
200
300
400
500
300
400
500
Water outlet BOD5mg/L
20
20
20
30
30
30
30
60
60
60
Treatment capacity
(m3/h)
A-0.5
0.5
0.4
0.33
0.5
0.4
0.38
0.3
0.5
0.43
0.38
A-1
1
0.8
0.65
1
0.9
0.75
0.6
1
0.85
0.75
A-3
3
2.4
1.95
3
2.7
2.55
1.8
3
2.55
2.55
A-5
5
4
3.25
5
4.5
3.75
3
5
4.25
3.75
A-10
10
8
6.5
10
9
7.5
6
40
8.5
7.5
A-20
20
16
13
20
18
15
12
20
17
15
A-30
30
24
19.5
30
27
22.5
18
30
25.5
22.5

4. Process flow chart

5. Height
Data
A-0.5
A-1
A-3
A-5
A-10
A-20
A-30
H
1500
1900
2400
2700
2600
2700
3000
H1
1000
1300
1800
2100
1800
1900
2100
H2
1000
1300
1700
2100
1600
1700
1800
DN1
80
80
80
80
100
100
100
DN2
80
80
100
100
100
125
125


[WSZ-F Module Type]

1. WSZ-F FRP type equipment is a kind of underground type complete organic sewage treatment package, which is applied for the treatment of domestic sewage and similar industrial organic sewage to ensure the treated water meeting the discharge standard required by the customers. WSH-F equipment with fully new structure made of FRP materials has pushed the technology and manufacturing skill of sewage treatment equipment to new higher stage, thus the sewage treatment equipments in this field has reached the international advanced level.

2. Technical data
Parameter
Water inlet
Water outlet
BOD5
100-200
20
CODcr
200-400
70
SS
200-450
30

TYPE
F-1
F-3
F-5
F-7.5
F-10
F-15
F-20
F-30
F-40
F-50
Treatment capacity (m3/h)
1
3
5
7.5
10
15
20
30
40
50
Equipment quantity
1
1
1
1
2
2
2
3
4
4
Sludge absorbing and primary sedimentation tank(m3)
1.8
5.5
9
14
18
27
36
50
80
100
Contact oxidization tankm3)
5.0
14.5
24
36
44
63
80
130
170
200
Surface load of secondary sedimentation tank (m3/m2h)
1.2
1.3
1.3
1.3
1.2
1.2
1.5
1.5
1.5
1.6
Disinfection tank (m3)
0.6
1.8
2.8
4
5.5
8
10
15
20
25
Blower
type
HC-25IS
HC-30IS
HC-50C
HC-50IS
HC-60S
HC-80S
HC-100S
HC-100S
HC-100S
HC-100S
power (kw)
0.4
0.75
1.5
2.2
2.2
3.7
5.5
5.5
5.5X2
5.5X2
amount
2
2
2
2
2
2
2
2
3
3
Water pump
type
AS10-2CB
AS16-2CB
AS20-2CB
power (kw)
1.0
1.6
2.9
Max. quantity (t)
5
6
7
10
8
10
10.5
10.5
10.5
12
Weight (t)
5.5
6.5
8
11
17
20
21
29
38
42
Floor area (m2)
8
14
20
30
50
65
75
115
155
185
All Rights Reserved. Copyright © 1992-2008